Product Description
Product description
SF1-6 High -efficiency, mute and compact
SF 1-6 is a complete vortex air compressor unit. It integrates vortex rotor, driving motor, rear cooler and a starter into a super quiet sound insulation cover in order to install it directly into your working environment. Not only that, you can also choose a full -performance model of the built -in frozen dryer. There are 3 installation methods for the air storage tank: the increase in 3 built -in 10L galvanized air storage tanks in the enlarged machine cover, and the horizontal air storage tank of 270L (72 gallons) or 500L (132 gallons).
Product Feature
Air intake filter
High -efficiency paper cylinder intake filter can filter dust and particles as small as 1um.
Automatic adjustment
When CHINAMFG the required pressure, the compressor will automatically stop, saving unnecessary energy consumption.
High -efficiency vortex rotation
Air-cooling vortex rotor, durable, reliable, and effective.
IP55 F Class / IE3 Motor
The completely closed air -cooling IP55 F -Class motor meets the energy efficiency standard of IE3 ultra -high -efficiency motor.
Frozen dryer
The compact and optimized built -in frozen dryer ensures to dry the compressed air and effectively prevent rust and corrosion of the air pipeline.
Specification
| Model | Max. Working pressure | Displacement | Motor mounting power | Noise level | Weight | |||||||||
| bar(e) | psig | l/s | m³/min | cfm | kW | hp | dB(A) | kg | lbs | |||||
| SF 1-6/2+-6+ (50/60 Hz) | ||||||||||||||
| SF 1 | 8 | 116 | 2.9 | 0.17 | 6.1 | 1.5 | 2 | 53 | 120 | 265 | ||||
| 10 | 145 | 1.9 | 0.11 | 4 | 1.5 | 2 | 53 | 120 | 265 | |||||
| SF 2 / SF 2+ | 8 | 116 | 4.2 | 0.25 | 8.9 | 2.2 | 3 | 55 | 125 | 276 | ||||
| 10 | 145 | 3.4 | 0.2 | 7.2 | 2.2 | 3 | 55 | 125 | 276 | |||||
| SF 4 / SF 4+ | 8 | 116 | 6.7 | 0.4 | 14.2 | 3.7 | 5 | 57 | 133 | 293 | ||||
| 10 | 145 | 5.9 | 0.35 | 12.5 | 3.7 | 5 | 57 | 133 | 293 | |||||
| SF 6 / SF 6+ | 8 | 116 | 9.8 | 0.59 | 20.8 | 5.5 | 7.5 | 59 | 157 | 346 | ||||
| 10 | 145 | 7.6 | 46 | 16.1 | 5.5 | 7.5 | 59 | 157 | 346 | |||||
| SF 8+-22+ (50/60 Hz) | ||||||||||||||
| SF 8+ | 8 | 116 | 13.4 | 0.8 | 28.4 | 7.4 | 10 | 63 | 485 | 1070 | ||||
| 10 | 145 | 11.4 | 0.68 | 24.2 | 7.4 | 10 | 63 | 485 | 1070 | |||||
| SF 11+ | 8 | 116 | 20.3 | 1.22 | 43 | 11 | 15 | 63 | 515 | 1135 | ||||
| 10 | 145 | 15 | 0.9 | 31.8 | 11 | 15 | 63 | 515 | 1135 | |||||
| SF 15+ | 8 | 116 | 26.4 | 1.58 | 55.9 | 14.8 | 20 | 63 | 580 | 1280 | ||||
| 10 | 145 | 23 | 1.38 | 48.7 | 14.8 | 20 | 63 | 580 | 1280 | |||||
| SF 17+ | 8 | 116 | 31 | 1.86 | 65.7 | 16.5 | 22 | 64 | 595 | 1315 | ||||
| 10 | 145 | 23.7 | 1.42 | 50.2 | 16.5 | 22 | 64 | 595 | 1315 | |||||
| SF 22+ | 8 | 116 | 40.8 | 2.45 | 86.5 | 22 | 30 | 65 | 680 | 1500 | ||||
| 10 | 145 | 30 | 1.8 | 63.6 | 22 | 30 | 65 | 680 | 1500 | |||||
| SFD 11+-22+ (50/60 Hz) | ||||||||||||||
| SFD 11+ | 8 | 116 | 9.8×2 | 0.59×2 | 20.8×2 | 11 | 15 | 63 | 625 | 1380 | ||||
| 10 | 145 | 7.6×2 | 0.46×2 | 16.1×2 | 11 | 15 | 63 | 625 | 1380 | |||||
| SFD 15+ | 8 | 116 | 13.4×2 | 0.80×2 | 28.4×2 | 14.8 | 20 | 64 | 755 | 1665 | ||||
| 10 | 145 | 11.4×2 | 0.68×2 | 24.2×2 4 | 14.8 | 20 | 64 | 755 | 1665 | |||||
| SFD 22+ | 8 | 116 | 19.2×2 | 1.21×2 | 2.8×2 | 22 | 30 | 65 | 840 | 1855 | ||||
| 10 | 145 | 5.0×2 | 0.90×2 | 31.8×2 | 22 | 30 | 65 | 840 | 1855 | |||||
| SF SKID/TWIN | ||||||||||||||
| Skid type | ||||||||||||||
| SF 1 | 8 | 116 | 2.9 | 0.17 | 6.1 | 1.5 | 2 | 65 | 105 | 232 | ||||
| 10 | 145 | 1.9 | 0.11 | 4 | 1.5 | 2 | 65 | 105 | 232 | |||||
| SF 2 | 8 | 116 | 4.2 | 0.25 | 8.9 | 2.2 | 3 | 67 | 110 | 243 | ||||
| 10 | 145 | 3.4 | 0.2 | 7.2 | 2.2 | 3 | 67 | 110 | 243 | |||||
| SF 4 | 8 | 116 | 6.6 | 0.4 | 14 | 3.7 | 5 | 68 | 120 | 265 | ||||
| 10 | 145 | 5.6 | 0.34 | 119 | 3.7 | 5 | 68 | 120 | 265 | |||||
| Twin type-twin air tank installation | ||||||||||||||
| SF 6T | 8 | 116 | 10.6 | 0.64 | 22.5 | 5.9 | 8 | 72 | 365 | 805 | ||||
| 10 | 145 | 9 | 0.54 | 19.1 | 5.9 | 8 | 72 | 365 | 805 | |||||
| SF 8T | 8 | 116 | 13.2 | 0.79 | 81.1 | 7.4 | 10 | 73 | 375 | 827 | ||||
| 10 | 145 | 11.2 | 0.67 | 68.8 | 7.4 | 10 | 73 | 375 | 827 | |||||
FAQ
Q1: What’s your delivery time?
A: 15 days to produce, within 3 days if in stock.
Q2: What’s methods of payments are accepted?
A: We agree T/T ,L/C , West Union ,Money Gram ,Paypal.
Q3: What about the shipments and package?
A: 40′ container for 2 sets, 20′ container for 1 set,
Machine in nude packing, spare parts in standard export wooden box.
Q4: Have you got any certificate?
A:We have got ISO,CE certificate.
Q5: How to control the quality?
A: We will control the quality by ISO and CE requests.
Q6: Do you have after-sale service and warranty service ?
A: Yes, we have.We can supply instruction for operation and maintenance.If necessary, we can send our engineer to repair the machine in your company.
Warranty is 1 year for the machine.
Q7: Can I trust your company ?
A: Our company has been certificated by Chinese government,and verified by SGS Inspection Company.
| After-sales Service: | Online |
|---|---|
| Lubrication Style: | Oil-free |
| Cooling System: | Air Cooling |
| Customization: |
Available
|
|
|---|
.shipping-cost-tm .tm-status-off{background: none;padding:0;color: #1470cc}
|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
|---|
| Payment Method: |
|
|---|---|
|
Initial Payment Full Payment |
| Currency: | US$ |
|---|
| Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
|---|
Can Water-Lubricated Compressors Be Used in High-Pressure Applications?
Water-lubricated compressors can be used in high-pressure applications, but there are certain considerations and limitations to keep in mind. Here’s a detailed explanation:
Water-lubricated compressors are typically designed for lower to medium-pressure ranges. They are commonly used in applications where the required discharge pressure does not exceed a certain threshold, typically up to a few hundred pounds per square inch (psi). However, there are specialized water-lubricated compressors available that can handle higher pressures, depending on the specific design and construction.
The ability of a water-lubricated compressor to operate at high pressures depends on several factors:
- Compressor Design: The design and construction of the compressor play a crucial role in determining its maximum pressure rating. Compressors designed for high-pressure applications need to have robust components, such as reinforced casings, high-strength materials, and proper sealing mechanisms to withstand the elevated pressures. Special attention should be given to the design of the water-lubricated bearing system to ensure it can handle the increased loads and pressures.
- Water Supply and Cooling: High-pressure compressors generate more heat during the compression process, requiring efficient cooling mechanisms to maintain safe operating temperatures. Sufficient water supply and cooling capacity must be available to handle the increased heat load. Adequate flow rates, temperature control, and cooling methods, such as water jackets or external cooling systems, may be necessary to prevent overheating and ensure proper lubrication and cooling of the compressor components.
- Water Quality: The quality of the water used for lubrication becomes even more critical in high-pressure applications. Any impurities, contaminants, or minerals present in the water can cause increased wear, corrosion, or blockages, jeopardizing the compressor’s performance and reliability. Water treatment or filtration systems may be required to maintain the desired water quality and prevent damage to the compressor.
- Sealing and Leakage Control: As the pressure increases, it becomes more challenging to maintain effective sealing and prevent leakage in the compressor system. Proper sealing mechanisms, such as high-quality seals and gaskets, are essential to ensure minimal leakage and maintain the required pressure levels. Adequate monitoring and maintenance of the sealing components are necessary to prevent energy losses and ensure the compressor’s efficiency.
It’s worth noting that for extremely high-pressure applications, water-lubricated compressors may not be the most suitable choice. In such cases, alternative lubrication methods, such as oil or specialized lubricants, are often preferred to handle the extreme pressures and provide adequate lubrication and cooling.
When considering the use of water-lubricated compressors in high-pressure applications, it is crucial to consult with the compressor manufacturer or a qualified engineer to ensure that the chosen compressor model is specifically designed and rated for the desired pressure range. Proper installation, maintenance, and adherence to the manufacturer’s guidelines are essential to ensure the safe and efficient operation of the compressor in high-pressure conditions.
Are There Any Restrictions on the Type of Water Used in Water-Lubricated Compressors?
When it comes to water-lubricated compressors, there are certain restrictions and considerations regarding the type of water that can be used. Here’s a detailed explanation of the restrictions on the type of water used in water-lubricated compressors:
Water Quality:
- Cleanliness: The water used in water-lubricated compressors should be clean and free from excessive impurities or contaminants. Impurities like sediment, minerals, or debris can cause blockages, wear, or damage to the compressor components. It is important to use water that meets the cleanliness requirements specified by the manufacturer.
- Chemical Composition: The chemical composition of the water can also be a factor to consider. Water with high mineral content or hardness can lead to scale formation, which can affect the performance and lifespan of the compressor. Water treatment methods, such as water softening or filtration, may be necessary to maintain the desired water quality.
Water Temperature:
- Freezing Point: In cold climates, it is important to ensure that the water used in the compressor’s lubrication system does not freeze. Freezing can cause operational issues and damage to the equipment. The water temperature should be maintained above freezing point through insulation, heating, or other suitable methods.
- Temperature Range: Water-lubricated compressors may have specific temperature requirements to ensure optimal operation and lubrication. Operating the compressor with water temperatures outside the recommended range can affect its performance and lifespan. It is important to adhere to the manufacturer’s guidelines regarding the acceptable temperature range for the water used.
Water Treatment:
- Water Treatment Systems: Depending on the quality of the available water supply, it may be necessary to use water treatment systems to ensure the water meets the required standards. Water treatment systems can help remove impurities, control chemical composition, and maintain the desired water quality for effective lubrication and cooling.
- Water Treatment Frequency: Regular maintenance and monitoring of the water treatment systems are essential to ensure their effectiveness. The frequency of water treatment, such as filtration or chemical treatment, may vary depending on the specific conditions and the water quality in the area.
Manufacturer Recommendations:
- Consulting the Manufacturer: It is important to consult the manufacturer’s guidelines and recommendations regarding the type of water to be used in water-lubricated compressors. Manufacturers may specify the acceptable water quality parameters, treatment methods, or restrictions to ensure optimal performance and longevity of the compressor.
By considering the cleanliness, chemical composition, temperature, and appropriate water treatment measures, the type of water used in water-lubricated compressors can be optimized to meet the requirements specified by the manufacturer. Adhering to these restrictions helps ensure efficient and reliable operation of the compressor while minimizing the risk of component damage or performance issues.
What Maintenance Is Required for Water-Lubricated Air Compressors?
Maintaining water-lubricated air compressors involves several key maintenance tasks to ensure their optimal performance and longevity. Here are the maintenance requirements typically associated with water-lubricated air compressors:
- Regular water quality checks: It is essential to monitor the quality of the water used for lubrication in the compressor. Regular water analysis helps identify any potential contaminants, such as minerals or impurities, that may affect compressor performance or lead to corrosion. If necessary, appropriate water treatment measures should be taken to maintain the desired water quality.
- Drain and flush water systems: Periodically draining and flushing the water systems of the compressor helps remove any sediment, debris, or accumulated contaminants. This prevents blockages, maintains water flow, and ensures the cleanliness of the system.
- Inspect and clean filters: Filters in the water system, such as intake filters or water separation filters, should be inspected regularly and cleaned or replaced as needed. Clean filters help maintain proper water flow, prevent clogging, and protect internal components from damage or corrosion.
- Check for leaks: Regularly inspect the compressor system for any signs of water leaks. Leaks can lead to water loss, reduced lubrication performance, and potential damage to the compressor components. Any identified leaks should be promptly repaired to maintain the integrity of the system.
- Monitor and maintain proper water levels: Ensure that the water levels in the compressor are maintained within the recommended range. Low water levels can result in inadequate lubrication and increased friction, while high water levels may lead to excessive moisture in the system. Regularly check and adjust the water levels as necessary.
- Inspect and maintain cooling systems: Water-lubricated compressors often utilize water for cooling purposes. Inspect and maintain the cooling systems, such as heat exchangers or radiators, to ensure proper heat dissipation. Clean any accumulated debris or deposits that may impede cooling efficiency.
- Follow manufacturer guidelines: It is crucial to follow the manufacturer’s maintenance guidelines and recommendations specific to the water-lubricated air compressor model being used. These guidelines may include additional maintenance tasks or intervals that are necessary for optimal performance and warranty compliance.
Regular and proactive maintenance of water-lubricated air compressors helps ensure their reliable operation, extends their lifespan, and minimizes the risk of performance issues or component failures. It is advisable to consult the compressor’s documentation and seek guidance from the manufacturer or a qualified technician to establish a comprehensive maintenance routine specific to the equipment.
editor by CX 2023-10-11
.webp)
.webp)
.webp)